On Sunday 27 October 2002 17:08, Marc Elsen wrote:
> Could there be induced bottlenecks as a result of the lan perimeter
> parameters ?
I doubt it.
> What kind of connection is being realized to the Intranet.
One server/gateway connected to a switch with 4 clients and a switch, which
holds 3 clients.
> Check port status on network hub, watch for possible errors over there.
There's no collision light, I'm afraid. Only link and activity.
> If the same file size is being transferred from the SQUID machine
> to a SQUID client, without SQUID, I mean , just ftp a file
> from the machine to the Intranet, are then the same bottlenecks
> observed ?
Nope. Just as with the request from the a webserver on the same box, it
transfers very quickly. FTP showed about 11 MB/s. Same file from same server.
I'm thinking if the bottleneck could be in the communication between squid and
the diskio (aufs) thread?
-- Regards, Tais M. Hansen OSDReceived on Sun Oct 27 2002 - 09:20:23 MST